Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Opt Express ; 31(12): 19703-19721, 2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-37381380

RESUMO

Methods of ablation imprints in solid targets are widely used to characterize focused X-ray laser beams due to a remarkable dynamic range and resolving power. A detailed description of intense beam profiles is especially important in high-energy-density physics aiming at nonlinear phenomena. Complex interaction experiments require an enormous number of imprints to be created under all desired conditions making the analysis demanding and requiring a huge amount of human work. Here, for the first time, we present ablation imprinting methods assisted by deep learning approaches. Employing a multi-layer convolutional neural network (U-Net) trained on thousands of manually annotated ablation imprints in poly(methyl methacrylate), we characterize a focused beam of beamline FL24/FLASH2 at the Free-electron laser in Hamburg. The performance of the neural network is subject to a thorough benchmark test and comparison with experienced human analysts. Methods presented in this Paper pave the way towards a virtual analyst automatically processing experimental data from start to end.

2.
J Synchrotron Radiat ; 30(Pt 1): 242-250, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36601943

RESUMO

The PERCIVAL detector is a CMOS imager designed for the soft X-ray regime at photon sources. Although still in its final development phase, it has recently seen its first user experiments: ptychography at a free-electron laser, holographic imaging at a storage ring and preliminary tests on X-ray photon correlation spectroscopy. The detector performed remarkably well in terms of spatial resolution achievable in the sample plane, owing to its small pixel size, large active area and very large dynamic range; but also in terms of its frame rate, which is significantly faster than traditional CCDs. In particular, it is the combination of these features which makes PERCIVAL an attractive option for soft X-ray science.


Assuntos
Fótons , Radiografia , Raios X
3.
Phys Rev Lett ; 108(25): 253003, 2012 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-23004594

RESUMO

Auger decay carries valuable information about the electronic structure and dynamics of atoms, molecules, and solids. Here we furnish evidence that under certain conditions Auger electrons are subject to an energetic chirp. The effect is disclosed in time-resolved streaking experiments on the Xe NOO and Kr MNN Auger decay using extreme-ultraviolet pulses from the free-electron laser in Hamburg as well as from a high-order harmonic laser source. The origin of this effect is found to be an exchange of energy between the Auger electron and an earlier emitted correlated photoelectron. The observed time-dependent spectral modulations are understood within an analytical model and confirmed by extensive computer simulations.

4.
Phys Rev Lett ; 108(9): 093401, 2012 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-22463632

RESUMO

Femtosecond x-ray laser flashes with power densities of up to 10(14) W/cm(2) at 13.7 nm wavelength were scattered by single xenon clusters in the gas phase. Similar to light scattering from atmospheric microparticles, the x-ray diffraction patterns carry information about the optical constants of the objects. However, the high flux of the x-ray laser induces severe transient changes of the electronic configuration, resulting in a tenfold increase of absorption in the developing nanoplasma. The modification in opaqueness can be correlated to strong atomic charging of the particle leading to excitation of Xe(4+). It is shown that single-shot single-particle scattering on femtosecond time scales yields insight into ultrafast processes in highly excited systems where conventional spectroscopy techniques are inherently blind.

5.
Phys Rev Lett ; 100(13): 133401, 2008 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-18517951

RESUMO

The interaction of intense extreme ultraviolet femtosecond laser pulses (lambda = 32.8 nm) from the FLASH free electron laser (FEL) with clusters has been investigated by means of photoelectron spectroscopy and modeled by Monte Carlo simulations. For laser intensities up to 5x10(13) W/cm(2), we find that the cluster ionization process is a sequence of direct electron emission events in a developing Coulomb field. A nanoplasma is formed only at the highest investigated power densities where ionization is frustrated due to the deep cluster potential. In contrast with earlier studies in the IR and vacuum ultraviolet spectral regime, we find no evidence for electron emission from plasma heating processes.

6.
Phys Rev Lett ; 98(20): 203001, 2007 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-17677687

RESUMO

Few-photon multiple ionization of Ne and Ar atoms by strong vacuum ultraviolet laser pulses from the free-electron laser at Hamburg was investigated differentially with the Heidelberg reaction microscope. The light-intensity dependence of Ne2+ production reveals the dominance of nonsequential two-photon double ionization at intensities of I<6x10(12) W/cm2 and significant contributions of three-photon ionization as I increases. Ne2+ recoil-ion-momentum distributions suggest that two electrons absorbing "instantaneously" two photons are ejected most likely into opposite hemispheres with similar energies.

7.
Opt Lett ; 31(11): 1750-2, 2006 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-16688283

RESUMO

Because of the stochastic nature of self-amplified spontaneous emission (SASE), it is crucial to measure for single pulses the spectral characteristics of ultrashort pulses from the vacuum ultraviolet free electron laser (FLASH) at DESY, Germany. To meet this particular challenge, we have employed both photon and photoelectron spectroscopy. Each FEL pulse is composed of an intense and spectrally complex fundamental, centered at a photon energy of about 38.5 eV, with a bandwidth of 0.5% accompanied by higher harmonics, each carrying an intensity of typically 0.3 to 0.6% of that of the fundamental. The correlation between the harmonics and the fundamental is in remarkable agreement with a simple statistical model of SASE FEL radiation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...